Locking Systems

Please view the various different locking systems we supply below. This page is only an overview, so please get in touch for more information

Public Lockers

locking wrist band

Our card locks can be exclusively card-operated, enabling members of an establishment to use lockers without having to supply a coin. Alternatively, in the case of facilities with both members and occasional users, our card locks can combine operation by cards and coins alike. Members access lockers with their cards and occasional users by inserting a coin. Card locks also prevent locker reservation because cards always have to be retrieved by users before they leave the premises.To avoid use by unauthorised persons, the card only works when punched with an exclusive card puncher available only from us.

Users can open or close lockers by simply pressing a porximity media card or bracelet (img to the right) against a door knob or handle


swimming lockers public locking system swimming lockers

OTS Transponder Lock

transponder lock

Stand alone or as part of an access control system, the OTS transponder lock is a secure choice. Users can open or close lockers by simply pressing a proximity media (card, or bracelet) against the door knob.

The transponder lock has a completely independent power system. It runs on four standard 1.5V AA batteries. The batteries will last for approximately 30,000 cycles so will need minimum attention for at least 2 years.

With the same footprint as coin locks, it is ideal for traditional lock replacements or upgrades.

Our transponder lock comes in two models: the standard OTS with the full range of integrated functions and the basic OTS, a cost-effective solution for facilities where only the basic level of functionality is required.

Both models are highly resistant to humidity, which makes them ideally suited to both dry and wet areas.

We offer different programming modes to ensure that lockers can be easily converted from dedicated mode into free mode, i.e. so that they can be assigned to a single user, be freely available to anyone or be designated to a defi ned user group.

MODEL OTS BASIC OTS
FUNCTIONS All functions integrated: Communication with programmer for updates and data collection Programmable in free or dedicated mode Groups supported Programmable in free mode only.
SPECIFICATIONS
POWER SUPPLY
BATTERY LIFE
DETECTION OF LOW BATTERY
COMMUNICATION INTERFACE
TECHNOLOGY
TEMPERATURE RANGE
PROTECTION AGAINST SOLID AND LIQUID BODIES
PROTECTION AGAINST EXTERNAL IMPACT
PROTECTION AGAINST INTERNAL IMPACT
DISPLAY
DIMENSIONS

4 AA 1.5V batteries
30,000 cycles
RS232
YES
Mifare 1k, 4k
-20º to +70º
IP55
IK7
IK9
Red, green, amber LED
109,5 x 35 x 118 mm

4 AA 1.5V batteries
30,000 cycles
YES
-
Mifare 1k, 4k
-20º a + 70º
IP55
IK7
IK9
-
109,5 x 35 x 118 mm

In the case of use with metal lockers, please contact us.

locking LED status

Below is a diagram showing an overview of the various locking systems we can provide. Please click on it for a larger view.

locking overview

Above left to right - CAM locks, latch bolt lock for dry areas, coin locks and the information terminal